This feature allows the opening or closing of a group of access points to be set using a single, swift action, either from Supervision or by a push button.

 

Set up an emergency action

1.Click on SET UP > Alarms/Alerts > Emergency actions. In the lower part of the screen are listed the actions that are already created.

2.Click on icn_add_black to add an action.

3.Enter a Description.

4.Indicate the Site on which the emergency function is to be installed (required in order to position the function on a graphical supervision plan).

5.Enter an Abbreviation and a Detailed description if necessary.

6.Select Input for manual release.

7.Choose one of the Application times:

a.Permanent (default choice - the access point(s) remain(s) in the status correlating with the type of action until the function is cancelled).

b.Time determined from 0:00:01 to 23:59:59 (0:00 by default and mandatory)

c.Time to set when calling function - The time to be set when calling the function is active only if the list of selected entries is empty.

8.Select the Type of action for access points and select the access points concerned from the list. Click on icn_3 dots to configure them. Validate.

9.Select the Type of action for Auto Events (Activation, Deactivation, Cause Fault Condition). Click on icn_3 dots to configure them. Check the items in the list of electrical equipment (auto events) to be controlled at the same time. Validate. This list may be empty.

icn_info

If the control relays or emergency buttons have been entered (access point control or electrical equipment alarm), the site is no longer able to be changed. In order to modify the site, all notions associated with the site must be removed before being able to modify it.

 

Clicking on Print allows you to print the emergency actions setup.