Event types

Auto events are set up according to conditions which may arise from the following events:

Access authorised/refused

Clocking authorised for one slot in the visit

Change in status of a dry contact input, relay output or reservation

Change in crossing schedule

Duress code

Condition valid if number of persons reached

A Reader Interface's power or connection is cut

Code entry error

Closure of unit casing

Attendance authorisation period end

End of authorisation period

Case opening

Door left open or forced

Power or connection is restored

Employee identified

According to planning

Set up an auto event condition

1.Click on SET UP > Auto events > Conditions.The lower part of the screen lists the elements already created.

2.Click on icn_add_black to add a condition.

3.Enter a Description.

4.Indicate the Site for which the condition will be applied (choice required from the dropdown menu).

icn_info

The conditions created for a site can only be used in auto events created for the same site.

5.Enter a Description for the condition.

6.Choose the First rule:

a.Select the Type of Event.

b.The Entry selection frame allows you to associate entries to a condition. Select entries using the icn_arrow_right and icn_double arrow_right arrows and then clicking on Validate.

c.Complete the additional fields which depend on the type of event for the 1st rule. For some types, there is no additional field.

7.If you want to add an Other rule, choose between And/Or.

a.Set the Sequence period between the two rules.

b.Choose the second Type of event.

8.Click the Save button to validate the creation of the condition.